Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 308
Filtrar
1.
J Mech Behav Biomed Mater ; 155: 106557, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38657286

RESUMO

The aim of this in vitro study was to evaluate the effect of the combinations of two different intraoral scanners (IOS), two milling machines, and two restorative materials on the marginal/internal fit and fatigue behavior of endocrowns produced by CAD-CAM. Eight groups (n= 10) were considered through the combination of TRIOS 3 (TR) or Primescan (PS) IOS; 4-axes (CR; CEREC MC XL) or 5-axes (PM; PrograMill PM7) milling machines; and lithium disilicate (LD; IPS e.max CAD) or resin composite (RC; Tetric CAD) restorative materials. Specific surface treatments were applied to each material, and the bonding to its corresponding Endocrown-shaped fiberglass-reinforced epoxy resin preparations was performed (Variolink Esthetic DC). Computed microtomography (µCT) was performed to assess the marginal/internal fit, as well as a mechanical fatigue test (20 Hz, initial load = 100 N/5000 cycles; step-size = 50 N/10,000 cycles until a threshold of 1500 N, then, the step-size was increased if needed to 100 N/10,000 cycles until failure or a threshold of 2800 N) to evaluate the restorations long-term behavior. Complementary analysis of the fracture features and surface topography in scanning electron microscopy was performed. Three-way ANOVA and Kaplan-Meier test (α = 0.05) were performed for marginal/internal fit, and fatigue behavior data, respectively. PS scanner, CR milling machine, and RC endocrowns resulted in a better marginal fit compared to their counterparts. Still, the PM machine resulted in a better pulpal space fit compared to the CR milling machine. Regardless of the scanner and milling machine, RC endocrowns exhibited superior fatigue behavior than LD ones. LD endocrowns presented margin chipping regardless of the milling machine used. Despite minor differences in terms of fit, the 'IOS' and 'milling machine' factors did not impair the fatigue behavior of endocrowns. Resin-composite restorations resulted in a higher survival rate compared to glass-ceramic ones, independently of the digital devices used in the workflow.

2.
Dent Med Probl ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661478

RESUMO

The challenge of dental ceramic degradation necessitates innovative technology, rigorous testing and proactive dental care, demanding collaboration between researchers, dentists and patients to ensure durable and reliable dental restorations.

3.
Int Dent J ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38461097

RESUMO

OBJECTIVE: The aim of the present study was to evaluate the influence of multidirectional brushing on the surface roughness, morphology, and bonding interface of resin-repaired CAD-CAM ceramic and composite restorations. MATERIALS AND METHODS: Twelve (N = 12) blocks (4 mm × 4 mm × 2 mm for parallel axis; 5 mm × 4 mm × 2 mm for perpendicular axis) of lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar AG) and CAD-CAM resin composite (Tetric CAD, Ivoclar AG) were obtained and repaired with direct resin composite (Clearfil AP-X, Kuraray). An abrasive slurry was prepared and the brushing was performed according to each restorative material and axis of brushing (n = 6; perpendicular to repair interface and parallel to repair interface) during 3,650 cycles (240 strokes per minute) to simulate 3 years of brushing. The surface roughness (Ra) and the profile variation for each material (restoration and direct repair resin composite) were measured at the baseline condition and after brushing, and the mean roughness and presence of steps at the repair interface were evaluated through factorial analysis of Variance (ANOVA). Scanning Electron Microscopy (SEM) images were taken to evaluate the surface topography of the repaired materials after brushing. RESULTS: The mean roughness of the repaired CAD-CAM restorations was affected by the brushing (P < .05), mainly when evaluating the repair material and the interface (P < .05), while the restorative CAD-CAM materials presented more stable values. The profile evaluation showed higher steps at the interface when repairing lithium disilicate than for CAD-CAM resin composite. CONCLUSION: Repaired CAD-CAM restorations were susceptible to wear after brushing simulation. The surface roughness of the direct resin composite was the most affected leading to step development at the interface, particularly in the repaired lithium disilicate samples. Cinical maintenance recalls and polishing protocols must be considered to enhance the longevity of such restorations.

4.
J Prosthet Dent ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38480018

RESUMO

STATEMENT OF PROBLEM: The influence of computer-aided manufacturing (CAM) parameters and settings on the outcomes of milled indirect restorations is poorly understood. PURPOSE: The purpose of this scoping review was to summarize the current CAM systems, parameters, and setting changes, and their effects on different outcomes of milled indirect restorations and aspects related to their manufacture. MATERIAL AND METHODS: The protocol of this review is available online (https://osf.io/x28ps/). Studies that used at least 2 different parameters (CAM units, number of axes, digital spacers, or protocols with different rotatory instruments, grit-sizes, milling speed, or others) for milling indirect restorations were included. A structured search up to July 2023 was performed by 2 independent reviewers for articles written in English in LILACS, MEDLINE via PubMed, EMBASE, Web of Science, and Scopus. RESULTS: Of 1546 studies identified, 22 were included in the review. Discrepancies were found between the planned and actual measured cement space, with a decreasing linear relationship impacting restoration adaptation at different points. The CEREC MC XL milling machine was the most used system in the included studies, with variations in bur types, milling modes, and number of burs uses affecting internal fit and surface trueness. The results demonstrated the better adaptation of restorations made with 5-axis over 3-axis milling machines. Lithium disilicate and zirconia were the most commonly used materials, and crowns and inlays were popular designs. Marginal and internal adaptation were the primary outcomes assessed using the various techniques. CONCLUSIONS: The study presented a comprehensive exploration of CAM systems and parameters, and their influence on indirect restorations. The planned cement space was not properly reproduced by the milling. Bur characteristics can affect restoration fit and trueness. The 5-axis units seem to result in better-adapted restorations compared with 3- and 4-axis units.

5.
Clin Oral Investig ; 28(2): 149, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38355823

RESUMO

OBJECTIVE: The study aims to evaluate the shear bond and flexural strength fatigue behavior of yttrium-stabilized zirconia (4YSZ) repaired using different resin composites. MATERIALS AND METHODS: Cylindric specimens of 4YSZ were obtained for the bond strength (Ø = 6 mm, 1.5 mm of thickness) and biaxial flexural strength (Ø = 15 mm, 1 mm of thickness) fatigue tests and divided into 3 groups according to the repair resin composite: EVO (nanohybrid), BULK (bulk-fill), and FLOW (flowable). The zirconia surface was air-abraded with alumina particles, a 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) primer was applied, and the resin composite was build-up over the zirconia. Fatigue shear bond strength and flexural fatigue strength tests were performed (n = 15). One-way ANOVA and Tukey post hoc tests were carried out for both outcomes, besides scanning electron microscopy and finite element analysis. RESULTS: The repair material affected the fatigue shear bond strength of zirconia ceramic. The BULK group (18.9 MPa) depicted higher bond strength values than FLOW (14.8 MPa) (p = 0.04), while EVO (18.0 MPa) showed similar results to both groups. No effect was observed for the mechanical behavior (p = 0.53). The stress distribution was similar for all groups. CONCLUSION: The repair of yttrium-stabilized zirconia (4YSZ) ceramics with bulk-fill resin composites was the best option for high fatigue bond strength. However, the fatigue mechanical performance was similar regardless of the applied repair material. CLINICAL RELEVANCE: The repair of yttrium-stabilized zirconia (4YSZ) monolithic restorations may be performed with nanohybrid and bulk-fill resin composites in order to promote longevity in the treatment.


Assuntos
Colagem Dentária , Metacrilatos , Colagem Dentária/métodos , Propriedades de Superfície , Teste de Materiais , Resinas Compostas/química , Zircônio/química , Cerâmica/química , Resistência ao Cisalhamento , Ítrio/química , Cimentos de Resina/química , Análise do Estresse Dentário
6.
PeerJ ; 12: e16942, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38406292

RESUMO

Despite the advancements in indirect monolithic restorations, technical complications may occur during function. To overcome this issues, intraoral repair using resin composite is a practical and low-cost procedure, being able to increase the restoration's longevity. This review aimed to evaluate the need for repair and suggest a standardized repair protocol to the main indirect restorative materials. For this, studies were surveyed from PubMed with no language or date restriction, to investigate the scientific evidence of indirect monolithic restoration repair with direct resin composite. A classification to guide clinical decisions was made based on the FDI World Dental Federation criteria about defective indirect restorations considering esthetic and functional standards, along with the patient's view, to decide when polishing, repairing or replacing a defective restoration. Based on 38 surveyed studies, different resin composite intraoral repair protocols, that included mechanical and chemical aspects, were defined depending on the substrate considering resin-based, glass-ceramic or zirconia restorations. The presented criteria and protocols were developed to guide the clinician's decision-making process regarding defective indirect monolithic restorations, prolonging longevity and increasing clinical success.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Humanos , Resinas Compostas/uso terapêutico , Resinas Vegetais , Inquéritos e Questionários
7.
Heliyon ; 10(1): e23709, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38187296

RESUMO

Objective: To evaluate the effect of different surface treatments on the morphology, shear bond, and flexural fatigue strength of a repaired translucent zirconia. Methods: Monolithic disc-shaped specimens of translucent zirconia were prepared and ground to simulate repair areas. Four groups underwent different treatments: Air-MDP (air-abrasion with alumina particles and 10-MDP primer), Si-Sil (silica-coated alumina particles with MDP-containing silane), Si-MDP (silica coating with 10-MDP primer), and Uni adhe (universal adhesive). After roughness measurements and treatments, repairs were done using resin composite. Shear bond and flexural (n = 15) fatigue tests were performed. Surface topography, interfacial analysis, fractographic, and finite element analysis were conducted. Results: The zirconia roughness was similar between the groups, however, the surface topography was modified according to the surface treatments. Si-Sil generated higher and more stable bond strength values (20.69 MPa) between translucent zirconia and resin composite when compared to Uni adhe (15.75 MPa) considering the fatigue bond strength scenario, while it was similar to Si-MDP (17.70 MPa) and Air-MDP (18.97 MPa). Regarding the mechanical behavior, Si-Sil (680.83 MPa) also showed higher and significantly different fatigue strength when compared to Uni adhe (584.55 MPa), while both were similar to Si-MDP (634.22 MPa) and Air-MDP (641.86 MPa). Conclusion: The association of mechanical and chemical approaches is essential for long-term bond strength and optimized mechanical behavior, being air-abrasion protocols and the use of silane and/or MDP-based primers suitable for zirconia repair protocols. It was found that relying solely on a universal adhesive was not as effective as other options available. Clinical significance: The surface treatment of repair protocols affects translucent zirconia's morphology. To enhance fatigue behavior in repaired monolithic zirconia, air abrasion is crucial. Exclusive use of a universal adhesive is less effective than other choices. A primer containing silane/MDP holds the potential for stable bond strength and optimized mechanical performance.

8.
J Mech Behav Biomed Mater ; 151: 106365, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38183746

RESUMO

This study aimed to evaluate the fatigue performance of simplified ceramic restorations (leucite-reinforced glass ceramic) adhesively cemented onto substrates of different resin composites. Three options from the same commercial line were selected (Tetric N-Line, Ivoclar), classified as Conventional (CRC), Bulk-fill (BRC) and Flowable (FRC), which were used to make discs using a cylindrical metallic device (n = 19; Ø = 10 mm, thickness = 2.0 mm). A total of 57 discs (Ø = 10 mm, thickness = 1.0 mm) were made from CAD/CAM prefabricated blocks of a leucite reinforced glass-ceramic (Empress CAD, Ivoclar) to simulate a monolithic restoration, then were randomly distributed to be bonded on 19 discs of each three different resin composite substrates (CRC; BRC; or FRC) with a dual resin cement (Multilink N; Ivoclar). The samples were subjected to a compression test with a hemispherical stainless-steel piston (Ø = 40 mm) at a monotonic regimen (n = 4; 1 mm/min loading rate and 500 kgf loading cell until fracture). The cyclic fatigue test was performed underwater at a frequency of 20 Hz (n = 15). The first step was applied using 200N for 5000 cycles, followed by increments of 50N at each step of 10,000 until failure. The outcome considered for both tests was the occurrence of radial crack. Specific statistical tests (α = 0.05) were performed for monotonic (One-way ANOVA; Tukey's test) and fatigue data (Kaplan-Meier test; Log-rank test). Fractography of fractured samples were also performed. The FRC group had the lowest failure load in both test regimes (p < 0.05; monotonic: 726.64N; fatigue: 716.67N). There were no differences between the CRC and BRC groups (p > 0.05; monotonic: 989.30 and 990.11N; fatigue: 810.00 and 833.33N, respectively). The same result was obtained considering cycles for fatigue failure (FRC < CRC=BRC). Leucite glass-ceramic bonded to substrates made of flowable resin composite behaves worse mechanically than bonding to conventional or bulk-fill resin composite substrates.


Assuntos
Silicatos de Alumínio , Cerâmica , Desenho Assistido por Computador , Propriedades de Superfície , Teste de Materiais , Suporte de Carga , Análise do Estresse Dentário , Porcelana Dentária , Falha de Restauração Dentária
9.
J Mech Behav Biomed Mater ; 150: 106338, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38159495

RESUMO

The aim of this study was to mechanically characterize through flexural fatigue test two CAD-CAM glass-ceramics according to distinct surface etching protocols. To do so, feldspathic (FELD) and lithium disilicate (LD) glass ceramics were subjected to different surface treatments: (1) control - no treatment (Ctrl); (2) conventional protocol etching with 5% hydrofluoric acid followed by silane coupling agent application (HF + SIL; Monobond N, Ivoclar); or (3) using a self-etching ceramic primer (E&P; Monobond Etch & Prime, Ivoclar). Ceramic discs (N = 120; Ø = 12 mm; thickness = 1.2 mm) were produced from CAD-CAM blocks, with 60 being from FELD (VITABLOCS Mark II, Vita Zahnfabrik) and 60 from LD (IPS e.max CAD, Ivoclar). Next, 20 disks of each ceramic were allocated into three groups: Ctrl, HF + SIL, or E&P. Surface roughness data were collected on all samples before and after surface treatments (except for Ctrl). Cyclic fatigue (n = 15) biaxial flexural strength tests were performed by the piston-on-three-balls geometry (ISO 6872) considering the test parameters established from a monotonic test (n = 5). The monotonic test was carried out at a 1 mm/min loading rate and 500 kgf loading cell until fracture to obtain the failure data. The cyclic fatigue test was executed underwater at a frequency up to 20 Hz, with the first stress being 25% of the monotonic test for 5000 cycles, followed by increments of 5% of the monotonic test at each step of 10,000 cycles until failure (fracture). Complementary fractography, topography and Atomic Force Microscopy (AFM) analyses were performed. Characteristic Fatigue Strength (CFS) and Weibull modulus were analyzed by Weibull analysis using the fatigue test data. Roughness and complementary analysis data were analyzed by one-way ANOVA. The statistical results exhibited similar CFS among Ctrl, HF + SIL and E&P for both glass-ceramics. The survival analysis corroborates the findings, however the Weibull modulus pointed out superior structural reliability of FELD treated with the E&P group compared to HF + SIL. According to the complementary analyses, HF + SIL exhibited a higher surface area than E&P and Ctrl for FELD (p = 0.001). Roughness showed statistically significant differences among conditions for FELD (E&P < Ctrl = HF + SIL; p < 0.05) and no difference for LD (p > 0.05). Therefore, the CFS were not influenced by any condition evaluated for FELD and LD glass-ceramics; however, superior structural reliability (higher Weibull modulus) for the feldspathic ceramic treated with the E&P was observed.


Assuntos
Colagem Dentária , Silanos , Propriedades de Superfície , Silanos/química , Ácido Fluorídrico , Reprodutibilidade dos Testes , Teste de Materiais , Condicionamento Ácido do Dente , Cerâmica/química , Porcelana Dentária , Análise do Estresse Dentário , Cimentos de Resina
10.
J Mech Behav Biomed Mater ; 148: 106233, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37976685

RESUMO

This study aimed to evaluate the effect of low and high viscosities of dual-cured resin cement on the mechanical fatigue behavior of yttria tetragonal zirconia polycrystals (3Y-TZP) and yttria-stabilized zirconia (4YSZ) adhesively luted to a dentin analogue (glass fiber-reinforced epoxy resin). Ceramic discs were randomly divided into four groups (n = 20) based on the following study factors: dual-cured resin cement viscosities (low and high) and zirconia microstructure (3Y-TZP and 4YSZ). The discs were treated by air abrasion with aluminum oxide particles (50 µm), followed by the application of primer, and then luted with high or low viscosity resin cement to the dentin analogue. Subsequently, the luted sets underwent a step-stress fatigue test, which involved an initial load of 200 N, step increments of 100 N, 10,000 cycles per step, and a frequency of 20 Hz. Data on fatigue failure load (FFL) and the number of cycles for failure (CFF) were collected and analyzed using survival tests, including Kaplan-Meier and Mantel-Cox analyses, as well as Weibull analysis. Additionally, topography analysis, fractographic features, bonding interface analysis, and Raman spectroscopy were performed. The results revealed that 3Y-TZP exhibited superior fatigue behavior compared to 4YSZ, regardless of the viscosity of the resin cement used for luting. Among all groups, 3Y-Low exhibited the best fatigue performance, while 4YSZ luted with low or high viscosity resin cements yielded the lowest fatigue behavior (FFL). There were no significant differences in Weibull modulus among the groups. After air abrasion, both ceramics showed similar topography. Raman analysis indicated that the surface of 3Y-TZP ceramics prior to sintering had a monoclinic phase, which transitioned predominantly to tetragonal phase peaks after sintering. A similar transition was observed in 4YSZ ceramics. In summary, 3Y-TZP exhibited superior mechanical fatigue behavior compared to 4YSZ. The influence of resin cement viscosity on fatigue behavior was more pronounced in 3Y-TZP, with low-viscosity resin cement enhancing its performance. However, the mechanical fatigue behavior of 4YSZ was less affected by the viscosity of the dual-cured resin cement, showing similar results with both low and high viscosities. In conclusion, 3Y-TZP demonstrated superior mechanical fatigue behavior compared to 4YSZ. The impact of resin cement viscosity on fatigue behavior was more pronounced in 3Y-TZP, with low-viscosity resin cement enhancing its performance. Conversely, the mechanical fatigue behavior of 4YSZ was less sensitive to the viscosity of the dual-cured resin cement, resulting in similar outcomes with both low and high viscosities.


Assuntos
Cerâmica , Cimentos de Resina , Cerâmica/química , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície , Viscosidade , Suporte de Carga , Ítrio/química , Zircônio/química
11.
Dent J (Basel) ; 11(11)2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37999018

RESUMO

This study evaluated the mechanical behavior and risk of failure of three CAD-CAM crowns repaired with different resin composites through a three-dimensional (3D) finite element analysis. Three-dimensional models of different cusp-repaired (conventional nanohybrid, bulk-fill, and flowable resin composites) crowns made of zirconia, lithium disilicate, and CAD-CAM resin composite were designed, fixed at the cervical level, and loaded in 100 N at the working cusps, including the repaired one. The models were analyzed to determine the Maximum Principal and Maximum Shear stresses (MPa). Complementary, an in vitro shear bond strength test (n = 10) was performed to calculate the risk of failure for each experimental group. The stress distribution among the models was similar when considering the same restorative material. The crown material affected the stress concentration, which was higher for the ceramic models (±9 MPa for shear stress; ±3 MPa for tensile stress) than for the CAD-CAM composite (±7 MPa for shear stress; ±2 MPa for tensile stress). The shear bond strength was higher for the repaired CAD-CAM resin composite (±17 MPa) when compared to the ceramics (below 12 MPa for all groups), while the repair materials showed similar behavior for each substrate. The stress distribution is more homogenous for repaired resin composite crowns, and a flowable direct resin composite seems suitable to repair ceramic crowns with less risk of failure.

12.
J Mech Behav Biomed Mater ; 148: 106169, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37837872

RESUMO

When partial and/or non-retentive preparation, such as those for occlusal veneers, is indicated, a proper and stable adhesion is essential. Therefore, the aim of this in vitro study was to evaluate the effect of loss of adhesion in different regions of the bonding interface on the fatigue behavior of simplified lithium disilicate restorations. For this, lithium disilicate (IPS e.max CAD) discs (1 mm thick and Ø = 10 mm) were fabricated, polished with #400-, #600-, #1200-grit silicon carbide (SiC) papers, and crystallized. As substrate, fiber-reinforced resin epoxy discs (2.5 mm thick and Ø = 10 mm) were fabricated and polished with #600-grit SiC paper. The ceramic bonding surface was treated with 5% hydrofluoric acid and a silane-containing primer (Monobond N), while the substrate was etched with 10% hydrofluoric acid followed by the application of the bonding system primers (Primer A + B). A lacquer (nail polish) was used to simulate the loss of adhesion in specific areas according to the study design to compose the testing groups: bonded (control; did not received nail polish application); - non-bonded (loss of adhesion in the whole specimen area); - margin (loss of adhesion in the ceramic margin); - center (loss of adhesion in the ceramic central area). The adhesive area of partially bonded groups was 50% of the adhesive surface. Then, the discs (n = 12) were bonded to the respective substrate using a resin cement (Multilink N), light-cured, water-stored for 90 days, and subjected to thermocycling (25,000 cycles, 5° to 55 °C) before testing. A cyclic fatigue test was run (20 Hz, initial load of 200 N for 5000 cycles, 50 N step size for 10,000 cycles each until specimen failure), and the fatigue failure load and number of cycles for failure were recorded. As complementary analysis, finite element analysis (FEA) and scanning electron microscopy analysis were performed. Kaplan-Meier log-rank (Mantel-Cox) was conducted for survival analysis. The results showed that as the loss of adhesion reaches the central area, the worse is the fatigue behavior and the higher is the stress peak concentration in the ceramic bonding surface. The bonded specimens presented better fatigue behavior and stress distribution compared to the others. In conclusion in a non-retentive preparation situation, proper adhesion is a must for the restoration fatigue behavior even after aging; while the loss of adhesion reaches central areas the mechanical functioning is compromised.


Assuntos
Cerâmica , Cimentos de Resina , Cerâmica/química , Cimentos de Resina/química , Ácido Fluorídrico/química , Propriedades de Superfície , Teste de Materiais , Análise do Estresse Dentário , Porcelana Dentária
13.
Clin Oral Investig ; 27(9): 5539-5548, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37490118

RESUMO

OBJECTIVE: To evaluate the effects of cusp inclination of the prosthetic preparation's occlusal surface and type of restorative material on the fatigue behavior, failure mode, and stress distribution of occlusal veneers. MATERIALS AND METHODS: Glass fiber-reinforced epoxy resin prosthetic preparations for occlusal veneers with three different occlusal surface cusp inclination degrees (0°, 15°, and 30°) were produced and assigned into six testing groups (n = 11) according to the cusp inclination (0°, 15°, or 30°) and type of restorative material (lithium disilicate-LD or resin composite-RC). Despite different substrate preparation cusp inclination degrees, the restorations were designed maintaining 30° inclination between the cusps at the occlusal surface and a thickness of 0.7 mm at the central groove region of the restorations to be machined in a CAD/CAM system. After cementation, the specimens were stored for about 7 days (under water at 37 °C), and subsequently submitted to a load to failure test (n = 2) and an intermittent cyclic fatigue test (n = 9) (initial load: 100 N; step size: 50 N; cycles/step: 10,000; loading frequency: 20 Hz; loading piston: 6-mm-diameter stainless steel) until observing cracks. The data were analyzed by two-way ANOVA, Kaplan-Meier, and Mantel-Cox post hoc tests. Finite element analysis (FEA) and fractographic analyses were performed. RESULTS: The fatigue performance of LD and RC occlusal veneers was evaluated based on different prosthetic preparation cusp inclinations. The 0° inclination showed the best fatigue performance for both materials (LD: 944N, RC: 861N), while the 15° and 30° inclinations had lower values (LD: 800N and 533N, RC: 739N and 717N, respectively). The study also found that for a 0° inclination, LD occlusal veneers performed better than RC ones (LD: 944 N > RC: 861N), while for a 30° inclination, RC occlusal veneers had better fatigue performance than LD ones (LD: 533N < RC: 717N). No significant difference was observed between the materials for a 15° inclination (LD: 800N = RC: 739N). The FEA results showed a higher tensile stress concentration on lithium disilicate than on resin composite occlusal veneers. All lithium disilicate occlusal veneers showed radial crack failures, while resin composite occlusal veneers showed Hertzian cone cracks and radial cracks combined. CONCLUSION: Considering mechanical perspective only, RC occlusal veneers should be indicated when prosthetic preparation cusps inclinations are 30°. When 0° prosthetic preparation cusps inclinations are observed, LD occlusal veneers will behave mechanically better. When a 15° cusp inclination is preserved, both restorative materials behave similarly.


Assuntos
Cerâmica , Porcelana Dentária , Teste de Materiais , Análise do Estresse Dentário , Resinas Compostas , Desenho Assistido por Computador , Falha de Restauração Dentária , Propriedades de Superfície
14.
J Prosthet Dent ; 130(2): 241.e1-241.e8, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37328406

RESUMO

STATEMENT OF PROBLEM: New computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate glass-ceramics have been marketed. However, information concerning their biomechanical behavior is lacking. PURPOSE: The purpose of this in vitro study was to compare the fit and fatigue behavior of two recently introduced CAD-CAM lithium disilicate materials with the standard IPS e.max CAD ceramic and to investigate the effect of the thermal treatment for crystallization on crown fit. MATERIAL AND METHODS: Monolithic crowns (n=15) were milled from 3 CAD-CAM lithium disilicates: IPS e.max CAD (Ivoclar AG), Rosetta SM (Hass), and T-lithium (Shenzhen Upcera Dental Technology). Marginal and internal fit were evaluated using the replica technique before and after crystallization, and the fatigue behavior of the luted crowns was evaluated by the step-stress method. One-way ANOVA and the Tukey test were used to compare fit among the materials. Fatigue failure load was evaluated by the Kaplan-Meier and Mantel-Cox tests. The effect of crystallization on fit was evaluated with the paired t test (α=.05). RESULTS: Marginal fit was different between IPS e.max CAD (74 µm) and Rosetta SM (63 µm) (P=.02). T-lithium was similar to the other ceramics (68 µm) (P>.05). Occlusal internal space was similar among all materials (P=.69). Fatigue failure loads of Rosetta SM (1160 N) and T-lithium (1063 N) were similar to IPS e.max CAD (1082 N) (P>.05). The fatigue failure load of Rosetta SM was higher than that of T-lithium (P=.04). Crystallization reduced the axial internal space of all materials (P<.05) without significantly affecting marginal fit (P>.05). CONCLUSIONS: The fit and fatigue behavior of Rosetta SM and T-lithium were similar to that of IPS e.max CAD. Crystallization reduced the internal space of the crowns.


Assuntos
Cerâmica , Lítio , Cerâmica/química , Planejamento de Prótese Dentária/métodos , Propriedades de Superfície , Adaptação Marginal Dentária , Técnica de Moldagem Odontológica , Análise do Estresse Dentário , Teste de Materiais , Porcelana Dentária/química , Coroas , Desenho Assistido por Computador
15.
J Mech Behav Biomed Mater ; 144: 105975, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37379673

RESUMO

OBJECTIVE: To summarize the existing scientific evidence on the effect of distinct intraoral (IOS) and extraoral (EOS) scanners in terms of their accuracy for image acquisition and the marginal/internal adaptation of indirect restorations. METHODS: The protocol of this scoping review is available online (https://osf.io/cwua7/). A structured search, with no date restriction, was performed in LILACS, MEDLINE via Pubmed, EMBASE, Web of Science, and Scopus, for articles written in English. The inclusion criteria were studies that considered at least two scanners, regardless of method (intra or extraoral), for the production of tooth-supported restorations. Two independent and blinded researchers screened the studies, collected and analyzed the data descriptively. RESULTS: 103 studies were included (55 on marginal/internal adaptation, 33 on accuracy, 5 on both outcomes, and 10 reviews). Most of them, shown clinically acceptable adaptation (<120 µm). Factors commonly related to the performance of scanners are: use of anti-reflection powders, method of image acquisition, and restoration/tooth characteristics. The need of anti-reflection powders was controversial. Different scanning principles seems to result on similar performance; IOS that combine them could be promising. The most explored systems were Omnicam - IOS, and inEos X5 - EOS, which showed similar performance on marginal/internal adaptation. Scarce studies explored the performance of EOS systems, especially in terms of accuracy. Different restoration designs as single-unit seemed not to modify the performance of scanners. Limited information is available regarding the planned cement space, restorative material and design (multi-unit restorations), as also techniques to measure adaptation. CONCLUSIONS: Digital scanners are valid approaches to obtain accurate impressions resulting in clinically acceptable restorations. Systems that uses combined principles of image acquisition seems promising for optimal performance. Based on high discrepancy, the quality of evaluated evidence is low, and well-designed studies are still encouraged, especially considering validated IOS/EOS as a control comparison condition.


Assuntos
Desenho Assistido por Computador , Dente , Pós , Planejamento de Prótese Dentária
16.
J Mech Behav Biomed Mater ; 142: 105854, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37130494

RESUMO

OBJECTIVE: To explore and characterize the effect of the discrepancy between crestal bone height (CB) and pulp chamber floor (PCF) in the fatigue performance of endodontically-treated teeth rehabilitated with an endocrown restoration. MATERIALS AND METHODS: A total of 75 human molars free of defects, caries history or cracks were selected, then endodontically treated and randomly allocated into 5 groups (N = 15) according to the difference between PCF and CB, as follows: PCF 2 mm above, PCF 1 mm above, PCF leveled, PCF 1 mm below and PCF 2 mm below. Endocrown restorations were made with composite resin (Tetric N-Ceram, shade B3, Ivoclar) in 1.5 mm thickness and luted with a resin cement (Multilink N, Ivoclar) onto the dental elements. Monotonic testing was performed to define the fatigue parameters, and a cyclic fatigue test was used until failure of the assembly. The collected data were submitted to statistical survival analysis (Kaplan-Meier followed by Mantel-Cox and Weibull), fractographic analysis and finite element analysis (FEA) were performed as complementary analyzes. RESULTS: The PCF 2 mm below and PCF 1 mm below groups presented the best results regarding fatigue failure load (FFL) and number of cycles for failure (CFF) (p < 0.05), but presented no difference between each other (p > 0.05). The PCF leveled and PCF 1 mm above groups presented no statistical difference between them (p > 0.05), but performed better than the PCF 2 mm above group (p < 0.05). The rate of favorable failures of PCF 2 mm above, PCF 1 mm above, PCF leveled, PCF 1 mm below and PCF 2 mm below groups were 91.7%, 100%, 75%, 66.7% and 41.7%, respectively. FEA showed different stress magnitudes according to the pulp-chamber design. CONCLUSION: The insertion level of the dental element to be rehabilitated with an endocrown interferes in the mechanical fatigue performance of the set. The discrepancy between the CB height and the PCF has a direct effect, where the higher the PCF in relation to the CB, the greater the risk of mechanical failure of the restored dental element.


Assuntos
Cavidade Pulpar , Dente não Vital , Humanos , Cerâmica , Resinas Compostas , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Dente Molar
17.
J Prosthodont ; 2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37201944

RESUMO

PURPOSE: This study evaluated the fatigue failure load (FFL) and the number of cycles for fatigue failure (CFF) of traditional (porcelain layer up) and reversed (zirconia layer up) designs of porcelain-veneered zirconia samples prepared with heat-pressing or file-splitting techniques. MATERIALS AND METHODS: Zirconia discs were prepared and veneered with heat-pressed or machined feldspathic ceramic. The bilayer discs were bonded onto a dentin-analog according to the bilayer technique and sample design: traditional heat-pressing (T-HP), reversed heat-pressing (R-HP), traditional file-splitting with fusion ceramic (T-FC), reversed file-splitting with fusion ceramic R-FC), traditional file-splitting with resin cement (T-RC), and reversed file-splitting with resin cement (R-RC). The fatigue tests were performed using the stepwise approach at 20 Hz, 10,000 cycles/step, step-size of 200 N starting at 600 N, and proceeding until failure detection or up to 2600 N if enduring. The failure modes (from radial and/or cone cracks) were analyzed in a stereomicroscope. RESULTS: The reversed design decreased the FFL and CFF of bilayers prepared with heat-pressing and file-splitting with fusion ceramic. The T-HP and T-FC reached the highest results, which were statistically similar between them. The bilayers prepared by the file-splitting with resin cement (T-RC and R-RC) were similar to the R-FC and R-HP groups regarding FFL and CFF. Almost all reverse layering samples failed by radial cracks. CONCLUSIONS: The reverse layering design did not improve the fatigue behavior of porcelain veneered zirconia samples. The three bilayer techniques behaved similarly when used in the reversed design.

18.
J Mech Behav Biomed Mater ; 142: 105794, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37037152

RESUMO

The aim of this study was to assess if the finishing/polishing of the bonding surface of lithium disilicate ceramic, prior to or after crystallization, would affect the fatigue behavior of a bonded restorations. For this, lithium disilicate ceramic (IPS e.max CAD) discs (n = 15) were milled and randomly divided into 3 groups: CAD-CAM group which remained untouched; PRE group which received a finishing/polishing protocol (OptraFine system) prior to its crystallization; and POST group, which received the treatment after its crystallization. After surface treatments, ceramic and glass-fiber reinforced epoxy resin discs were paired and bonded using a resin cement (Multilink N). A cyclical fatigue test was conducted (frequency 20 Hz, initial load 200 N for 5000 cycles, step-size of 100 N for 10,000 cycles/step) until failure occurrence. Surface roughness and topography were analyzed. An initial descriptive analysis of surface roughness, FFL and CFF was performed to obtain the mean, standard deviation and confidence interval values (SPSS v. 21, SPSS Inc.) for statistical analysis. Roughness data was using one-way ANOVA with Tukey's post hoc test (α = 0.05), while the fatigue data was submitted to survival analysis with Kaplan-Meier test (α = 0.05) and Weibull modulus (Weibull++, Reliasoft). Neither the finishing/polishing procedure of the bonding surface, nor the moment (prior to or after crystallization), affected the fatigue behavior of bonded milled lithium disilicate. There were also no differences for mechanical reliability among conditions. Despite this, finishing/polishing reduced surface roughness and led to smoother topography. Finishing/polishing the bonding surface of milled lithium disilicate, before or after crystallization, does not alter the fatigue behavior of the bonded restorative set, although there is some influence on roughness and topography.


Assuntos
Cerâmica , Porcelana Dentária , Propriedades de Superfície , Teste de Materiais , Cristalização , Reprodutibilidade dos Testes , Cerâmica/química , Desenho Assistido por Computador , Análise do Estresse Dentário
19.
J Mech Behav Biomed Mater ; 142: 105829, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37068429

RESUMO

The purpose of the present study was to characterize the elastic modulus and Poisson's ratio of a resin cement with distinct viscosities, and to evaluate their impact on the static and fatigue strength of a translucent zirconia (4Y-PSZ) after air-abrasion surface treatment. Bar-shaped specimens of two different viscosities of resin cement (high and low) were obtained (25 × 10 × 3 mm). Sonelastic and Maxwell principles tests were performed to determine the elastic modulus and Poisson's ratio of each resin cement. Disc-shaped specimens of 4Y-PSZ were made (Ø = 15 mm, 1.2 mm in thickness) for the mechanical tests and allocated into groups according to two factors: surface treatment (presence or absence of air-abrasion with alumina particles; 45 µm grain-size); cement (absence, low or high viscosity). The static (n = 10) and cyclical (n = 15) biaxial flexural strength tests were performed by piston-on-three-balls geometry. A fatigue strength test was executed (20 Hz, initial stress of 60 MPa [12% of the mean static biaxial flexural strength], followed by increments of 25 MPa [5% of the mean static biaxial flexural strength] at each step of 10,000 cycles until the failure). The obtained data were analyzed by Weibull analysis. Survival rates were tabulated by the Kaplan-Meier test. Complementary analyses of surface roughness, topography, cross-sectional interfacial zone, fractography, and zirconia crystalline content (X-ray diffraction) were also performed. The evaluated resin cements with high and low viscosity presented similar elastic modulus (13.63 GPa; 12.74 GPa) and Poisson's ratio (0.32; 0.30), respectively. The air-abraded groups depicted higher mechanical strength of the zirconia ceramics than non-abraded groups (p˂ 0.05), regardless of the resin cement. 4Y-PSZ adhesively bonded to a high or low viscosity resin cement have statistically similar behavior (p˃ 0.05). The mechanical structural reliability of the 4Y-PSZ was not affected by the factors. Therefore, resin cement with high and low viscosity presented similar properties and potential to fill the zirconia surface, and did not affect the mechanical behavior of 4Y-PSZ. However, the air-abrasion surface treatment increased the static and fatigue flexural strength of the translucent zirconia.


Assuntos
Cimentos de Resina , Zircônio , Teste de Materiais , Cimentos de Resina/química , Viscosidade , Reprodutibilidade dos Testes , Estudos Transversais , Suporte de Carga , Zircônio/química , Cerâmica/química , Propriedades de Superfície , Análise do Estresse Dentário
20.
J Mech Behav Biomed Mater ; 142: 105819, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37062098

RESUMO

OBJECTIVE: To evaluate the influence of intaglio ceramic surface treatments, resin cement viscosities, and storage regimens on the microshear bond strength of lithium disilicate ceramic. In addition, to investigate the dynamic viscosity of the resin-based luting agents. MATERIALS AND METHODS: Ceramic slices were randomly allocated into eight groups (n = 19) considering three factors: ceramic surface treatment (hydrofluoric acid followed by silane, HF; or self-etching ceramic primer, E&P), resin cement viscosity (high, HIGH; or low, LOW) and storage regimen (baseline or aging). Surface treatments were performed, resin cement cylinders were built and microshear bond strength tests (µSBS, wire-loop method, speed: 1.0 mm/min) were run according to the storage factor. Failure mode, topographic and dynamic viscosity (37 °C; shear rate of 1.0-100 s-1) of resin cement components (base, high and low catalyst) were also performed. RESULTS: Resin cement viscosity and the association among ceramic surface treatment, resin cement viscosity, and storage regimen were statistically significant factors (p < 0.05). Worse behavior was identified for the E&P_HIGH group compared to the E&P_LOW and HF_LOW in the baseline condition. After aging, the HF_HIGH group (16.78 MPa) presented the worst result among the aged groups (21.44-25.25 MPa). Most of the failures were adhesive. Surface micrographs revealed a distinct pattern after etching, more aggressive by HF and milder by E&P. High viscosity catalyst is 5.3 and 8.5-fold more viscous than the base and low viscosity catalyst, respectively (high > base > low). CONCLUSION: Differences in filler content can impact the resin viscosity of the material (more fillers increase the viscosity), which in turn can influence the bond strength of a lithium disilicate ceramic, depending on the surface treatment and storage regimen.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Viscosidade , Propriedades de Superfície , Teste de Materiais , Cerâmica , Porcelana Dentária , Ácido Fluorídrico , Silanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...